At Aviation Parts Circuit, we offer an unparalleled selection of parts for the aerospace, civil aviation, defense, electronics, and IT hardware markets. Owned and operated by ASAP Semiconductor, we have access to an inventory of more than two billion new and obsolete parts organized into an efficient, streamlined, and easy-to-navigate purchasing platform. Part numbers such as TR958, which is a Transformer Power from manufacturer Sora Power Inc, are in stock and ready to ship with short lead times and competitive prices. We specialize in leveraging our purchasing power with major suppliers, allowing us to offer lower costs and faster shipping on all orders, even in AOG situations. Our team at Aviation Parts Circuit is available 24/7x365 to provide you with a quick quotation on part TR958 and any other NSN part listed on our website.
To help users quickly locate the parts they need, our website offers a broad scope of parametric search measures, allowing customers to filter parts by their Federal Supply Group or Class, part type, part family, CAGE Code, NSN, and more. For example, if you are in need of Sora Power Inc parts from NSN 5950002366391, our website can provide you with a selection of parts exclusively from that manufacturer and NSN. At Aviation Parts Circuit, our goal is not only to improve the parts procurement process, but to revolutionize it entirely. To begin the NSN part TR958 purchasing process instantly, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-236-6391 Item Description: Transformer Power | 5950 | 002366391 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Tr958 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.213 INCHES NOMINAL SINGLE GROUP0.213 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4.656 INCHES NOMINAL4.656 INCHES NOMINAL |
ADAT | BODY WIDTH | 3.218 INCHES NOMINAL3.218 INCHES NOMINAL |
ADAU | BODY HEIGHT | 4.120 INCHES MAXIMUM4.120 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 10 SECONDARY SINGLE COMPONENT10 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 125.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 150.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 150.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 85.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY800.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 39.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 75.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 75.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY39.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 800.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | PRIMARY WINDING; TEN SECONDARY WINDINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 26 WIRE LEAD |