At Aviation Parts Circuit, we offer an unparalleled selection of parts for the aerospace, civil aviation, defense, electronics, and IT hardware markets. Owned and operated by ASAP Semiconductor, we have access to an inventory of more than two billion new and obsolete parts organized into an efficient, streamlined, and easy-to-navigate purchasing platform. Part numbers such as 73C828-004, which is a Transformer Power from manufacturer Pulse Electronics Corporation, are in stock and ready to ship with short lead times and competitive prices. We specialize in leveraging our purchasing power with major suppliers, allowing us to offer lower costs and faster shipping on all orders, even in AOG situations. Our team at Aviation Parts Circuit is available 24/7x365 to provide you with a quick quotation on part 73C828-004 and any other NSN part listed on our website.
To help users quickly locate the parts they need, our website offers a broad scope of parametric search measures, allowing customers to filter parts by their Federal Supply Group or Class, part type, part family, CAGE Code, NSN, and more. For example, if you are in need of Pulse Electronics Corporation parts from NSN 5950002397547, our website can provide you with a selection of parts exclusively from that manufacturer and NSN. At Aviation Parts Circuit, our goal is not only to improve the parts procurement process, but to revolutionize it entirely. To begin the NSN part 73C828-004 purchasing process instantly, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-239-7547 Item Description: Transformer Power | 5950 | 002397547 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
73c828-004 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.552 INCHES MINIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP AND 3.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 1.572 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP3.141 INCHES MAXIMUM SINGLE MOUNTING FACILIT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.990 INCHES MINIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP AND 1.672 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 1.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP1.704 INCHES MAXIMUM SINGLE MOUNTING FACILIT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.672 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.672 INCHES MINIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.859 INCHES MINIMUM AND 1.891 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.859 INCHES MINIMUM AND 3.891 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.172 INCHES MINIMUM AND 2.204 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP AND 1.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 1ST GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 2ND GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 3RD GROUP2 1ST GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 4TH GROUP4 2ND GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE ALL GROUPINGS |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES 2ND GROUP |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES 3RD GROUP0.138 INCHES 1ST GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES 1ST GROUP |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES 4TH GROUP0.112 INCHES 2ND GROUP |
CRBZ | WINDING OPERATING CURRENT | 40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 84.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 1.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY5.46 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 1.8 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY41.52 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 41.52 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 5.46 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1.038 AC KILOVOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY65.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 3.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY1.038 AC KILOVOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 39.20 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 40.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY8.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 65.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 8.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY39.20 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
FEAT | SPECIAL FEATURES | TWO PRIMARY WINDINGS; SIX SECONDARY WINDINGS |
TEST | TEST DATA DOCUMENT | 04660-73C828 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
THSD | THREAD SERIES DESIGNATOR | UNC ALL GROUPINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 25 TURRET |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote