At Aviation Parts Circuit, we offer an unparalleled selection of parts for the aerospace, civil aviation, defense, electronics, and IT hardware markets. Owned and operated by ASAP Semiconductor, we have access to an inventory of more than two billion new and obsolete parts organized into an efficient, streamlined, and easy-to-navigate purchasing platform. Part numbers such as 33237, which is a Filter Band Pass from manufacturer K And L Microwave Inc, are in stock and ready to ship with short lead times and competitive prices. We specialize in leveraging our purchasing power with major suppliers, allowing us to offer lower costs and faster shipping on all orders, even in AOG situations. Our team at Aviation Parts Circuit is available 24/7x365 to provide you with a quick quotation on part 33237 and any other NSN part listed on our website.
To help users quickly locate the parts they need, our website offers a broad scope of parametric search measures, allowing customers to filter parts by their Federal Supply Group or Class, part type, part family, CAGE Code, NSN, and more. For example, if you are in need of K And L Microwave Inc parts from NSN 5915012621719, our website can provide you with a selection of parts exclusively from that manufacturer and NSN. At Aviation Parts Circuit, our goal is not only to improve the parts procurement process, but to revolutionize it entirely. To begin the NSN part 33237 purchasing process instantly, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-262-1719 Item Description: Filter Band Pass | 5915 | 012621719 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | S | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
33237 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.720 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 0.380 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 3.780 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.320 INCHES NOMINAL |
ADAT | BODY WIDTH | 3.500 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.120 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.520 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.000 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -46.0/+75.0 DEG CELSIUS |
AFSV | AVERAGE LIFE RATING IN HOURS | 10000.0 |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 620.0 HERCULES NO.5599.1 PULSES PER SECOND |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 640.0 HERCULES NO.5599.1 HERTZ |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 660.0 HERCULES NO.5599.1 TWO PHASE TO TWO PHASE |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 680.0 HERCULES NO.5599.1 TWO PHASE TO THREE PHASE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST BAND PASS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND BAND PASS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD BAND PASS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH BAND PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST BAND PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND BAND PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD BAND PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH BAND PASS |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST BAND PASS 1ST FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND BAND PASS 2ND FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD BAND PASS 3RD FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH BAND PASS 4TH FUNCTION |
AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.5 1ST BAND PASS |
AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.5 2ND BAND PASS |
AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.5 3RD BAND PASS |
AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.5 4TH BAND PASS |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 5.0 1ST BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 5.0 2ND BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 5.0 3RD BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 5.0 4TH BAND PASS |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 PIN INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 PIN OUTPUT 2ND FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 600.00 MEGAHERTZ 1ST BAND PASS 1ST FUNCTION AND 619.00 MEGAHERTZ 1ST BAND PASS 1ST FUNCTION AND 621.00 MEGAHERTZ 1ST BAND PASS 1ST FUNCTION AND 640.00 MEGAHERTZ 1ST BAND PASS 1ST FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 620.00 MEGAHERTZ 4TH BAND PASS 4TH FUNCTION AND 639.00 MEGAHERTZ 4TH BAND PASS 4TH FUNCTION AND 641.00 MEGAHERTZ 4TH BAND PASS 4TH FUNCTION AND 660.00 MEGAHERTZ 4TH BAND PASS 4TH FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 640.00 MEGAHERTZ 2ND BAND PASS 2ND FUNCTION AND 659.00 MEGAHERTZ 2ND BAND PASS 2ND FUNCTION AND 661.00 MEGAHERTZ 2ND BAND PASS 2ND FUNCTION AND 680.00 MEGAHERTZ 2ND BAND PASS 2ND FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 660.00 MEGAHERTZ 3RD BAND PASS 3RD FUNCTION AND 679.00 MEGAHERTZ 3RD BAND PASS 3RD FUNCTION AND 681.00 MEGAHERTZ 3RD BAND PASS 3RD FUNCTION AND 700.00 MEGAHERTZ 3RD BAND PASS 3RD FUNCTION |
CQRG | BODY MATERIAL | ALUMINUM |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 619.00 MEGAHERTZ 1ST BAND PASS AND 621.00 MEGAHERTZ 1ST BAND PASS |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 639.00 MEGAHERTZ 4TH BAND PASS AND 641.00 MEGAHERTZ 4TH BAND PASS |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 659.00 MEGAHERTZ 2ND BAND PASS AND 661.00 MEGAHERTZ 2ND BAND PASS |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 679.00 MEGAHERTZ 3RD BAND PASS AND 681.00 MEGAHERTZ 3RD BAND PASS |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 40.0 MINIMUM 1ST BAND PASS 1ST FUNCTION AND 5.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION AND 5.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION AND 40.0 MINIMUM 1ST BAND PASS 1ST FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 40.0 MINIMUM 2ND BAND PASS 2ND FUNCTION AND 5.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION AND 5.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION AND 40.0 MINIMUM 2ND BAND PASS 2ND FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 40.0 MINIMUM 3RD BAND PASS 3RD FUNCTION AND 5.0 MAXIMUM 3RD BAND PASS 3RD FUNCTION AND 5.0 MAXIMUM 3RD BAND PASS 3RD FUNCTION AND 40.0 MINIMUM 3RD BAND PASS 3RD FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 40.0 MINIMUM 4TH BAND PASS 4TH FUNCTION AND 5.0 MAXIMUM 4TH BAND PASS 4TH FUNCTION AND 5.0 MAXIMUM 4TH BAND PASS 4TH FUNCTION AND 40.0 MINIMUM 4TH BAND PASS 4TH FUNCTION |
CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | 619.0 HERCULES NO.5599.1 PULSES PER SECOND AND 621.0 HERCULES NO.5599.1 PULSES PER SECOND |
CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | 639.0 HERCULES NO.5599.1 HERTZ AND 641.0 HERCULES NO.5599.1 HERTZ |
CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | 659.0 HERCULES NO.5599.1 TWO PHASE TO TWO PHASE AND 661.0 HERCULES NO.5599.1 TWO PHASE TO TWO PHASE |
CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | 679.0 HERCULES NO.5599.1 TWO PHASE TO THREE PHASE AND 681.0 HERCULES NO.5599.1 TWO PHASE TO THREE PHASE |
PMLC | PRECIOUS MATERIAL AND LOCATION | TERMINAL SURFACES SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote