Quality guaranteed We sell only warrantied and traceable partsAt Aviation Parts Circuit, we offer an unparalleled selection of parts for the aerospace, civil aviation, defense, electronics, and IT hardware markets. Owned and operated by ASAP Semiconductor, we have access to an inventory of more than two billion new and obsolete parts organized into an efficient, streamlined, and easy-to-navigate purchasing platform. Part numbers such as 2-14400-02, which is a Power Supply Assemb from manufacturer Excelitas Technologies Corp, are in stock and ready to ship with short lead times and competitive prices. We specialize in leveraging our purchasing power with major suppliers, allowing us to offer lower costs and faster shipping on all orders, even in AOG situations. Our team at Aviation Parts Circuit is available 24/7x365 to provide you with a quick quotation on part 2-14400-02 and any other NSN part listed on our website.
To help users quickly locate the parts they need, our website offers a broad scope of parametric search measures, allowing customers to filter parts by their Federal Supply Group or Class, part type, part family, CAGE Code, NSN, and more. For example, if you are in need of Excelitas Technologies Corp parts from NSN 6130013173680, our website can provide you with a selection of parts exclusively from that manufacturer and NSN. At Aviation Parts Circuit, our goal is not only to improve the parts procurement process, but to revolutionize it entirely. To begin the NSN part 2-14400-02 purchasing process instantly, submit an RFQ today.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 6130-01-317-3680 Item Description: Power Supply Assemb | 6130 | 013173680 | 0 | N | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | 0 | ||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 2-14400-02 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 49.500 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 8.000 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 35.000 INCHES NOMINAL |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| AMKG | POWER UNIT TYPE | TRANSFORMER POWER STEP-UP SINGLE OPERATING POWER RQMT |
| AMQY | INSTALLATION DESIGN | PANEL |
| ANPM | INPUT PHASE | THREE SINGLE OPERATING POWER RQMT |
| APNX | INPUT VOLTAGE RATING | 115.0 AC POUNDS PER HOUR WET SINGLE OPERATING POWER RQMT |
| APPA | III OUTPUT VOLTAGE RATING | -28.0 DC VOLTS MINIMUM AND 30.0 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
| APPA | III OUTPUT VOLTAGE RATING | 15.0 DC VOLTS MINIMUM AND 16.5 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
| APPA | III OUTPUT VOLTAGE RATING | 5.0 DC VOLTS MINIMUM AND 6.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
| APTQ | INPUT FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT |
| BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 1ST POWER OUTPUT |
| BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
| BGQF | POWER UNIT QUANTITY | 1 |
| CWGH | OUTPUT CURRENT RATING | 0.0 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 80.0 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
| CWGW | POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICS | CONSTANT VOLTAGE 1ST POWER OUTPUT |
| CWGW | POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICS | CONSTANT VOLTAGE 3RD POWER OUTPUT |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 1ST POWER OUTPUT |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 3RD POWER OUTPUT |
| CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
| CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP SINGLE OPERATING POWER RQMT |
| CWHT | INPUT CONNECTION QUANTITY | 1 SINGLE OPERATING POWER RQMT |
| CXNJ | POWER SUPPLIES PROGRAMMED PER SYSTEM | 3 |
| BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 3RD POWER OUTPUT |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 2ND POWER OUTPUT |
| ADZC | ENVIRONMENTAL PROTECTION | DRIPPROOF |
| CBBL | FEATURES PROVIDED | DC VOLTMETER AND FUSE AND INDICATOR LIGHT |
| CWGH | OUTPUT CURRENT RATING | 0.0 DC AMPERES MINIMUM 3RD POWER OUTPUT AND 2.0 DC AMPERES MAXIMUM 3RD POWER OUTPUT |
| CWGW | POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICS | CONSTANT VOLTAGE 2ND POWER OUTPUT |
| CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
| CWKG | VENTILATION DESIGN TYPE | CONVECTION |
| AGAV | END ITEM IDENTIFICATION | SHIP CONTROL STATION |
| AYNH | OPERATING AMBIENT TEMP RANGE | +0.0/+65.0 DEG CELSIUS |
| CWGH | OUTPUT CURRENT RATING | 0.0 DC AMPERES MINIMUM 1ST POWER OUTPUT AND 4.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
| CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 3RD POWER OUTPUT |
![]() |