At Aviation Parts Circuit, we offer an unparalleled selection of parts for the aerospace, civil aviation, defense, electronics, and IT hardware markets. Owned and operated by ASAP Semiconductor, we have access to an inventory of more than two billion new and obsolete parts organized into an efficient, streamlined, and easy-to-navigate purchasing platform. Part numbers such as 32-2115, which is a Transformer Power from manufacturer Carol Electronics Div Of Watson, are in stock and ready to ship with short lead times and competitive prices. We specialize in leveraging our purchasing power with major suppliers, allowing us to offer lower costs and faster shipping on all orders, even in AOG situations. Our team at Aviation Parts Circuit is available 24/7x365 to provide you with a quick quotation on part 32-2115 and any other NSN part listed on our website.
To help users quickly locate the parts they need, our website offers a broad scope of parametric search measures, allowing customers to filter parts by their Federal Supply Group or Class, part type, part family, CAGE Code, NSN, and more. For example, if you are in need of Carol Electronics Div Of Watson parts from NSN 5950003769596, our website can provide you with a selection of parts exclusively from that manufacturer and NSN. At Aviation Parts Circuit, our goal is not only to improve the parts procurement process, but to revolutionize it entirely. To begin the NSN part 32-2115 purchasing process instantly, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-376-9596 Item Description: Transformer Power | 5950 | 003769596 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
32-2115 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.000 INCHES NOMINAL3.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.469 INCHES NOMINAL2.469 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.844 INCHES NOMINAL2.844 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALEDHERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT3 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP32 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP0.138 INCHES SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 130.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 365.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 545.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 780.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 130.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY365.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 545.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 780.00 AC V |
CWJS | WINDING OPERATING VOLTAGE | 130.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY365.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 545.00 AC VOLTS NO |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 12 STANDOFF, SOLDER LUG |